Uses
- Acoustical and electrical calibration of sound level meters to international standards
| Features
- Automatic, semi-automatic or manual calibration of sound level meters
- Runs under Microsoft® Windows®
- Flexible test-execution manager
- Integrated Calibration Manager’s Workbench with: – traceability control – customer database
- Predefined or user-defined calibration sequences
- Transparent user interface
- Test signals comply with IEC 60651 and IEC 60804
- IEC 61672 tests available as an upgrade
- Default acceptance limits set in accordance with IEC-type Sound Level Meters
- User-adaptable acceptance limits (OIML requirements)
- Taktmaximal Tests (DIN 45657)
- External electrical traceability via system’s digital voltmeter
- External acoustic traceability via Multifunction Acoustic Calibrator Type 4226
- Built-in system verification of measurement quality
- Flexible Certificate of Calibration with detailed test report
- Fully integrated in the Microsoft® Office environment
|
System Concept
The new generation of calibration systems from Brüel & Kjær uses the Portable PULSE™ analyzer as the core system element. Portable PULSE is a state-of-the-art, highly flexible multi-analyzer capable of analysing by FFT, 1/n-octave filters and overall levels. PULSE also generates the test signals necessary to fulfill the requirements of international standards.
The Sound Level Meter Calibration system for the Type 3630 platform is designed to calibrate Brüel & Kjær as well as other manufacturers’ sound level meters, according to IEC 60651, IEC 60804 and relevant ANSI standards. Future upgrades will cover the coming IEC 61672 standard.
Integrated Applications
Previously, different applications would typically run on dedicated, stand-alone systems. However, all applications on the new platform are fully integrated. This means that information entered just once, for example, customer information, is available to all applications which guarantees data integrity and saves you time. Furthermore, the system’s integration with the Microsoft® Office environment assures data compatibility facilitating data export for analysis.
Calibration Manager’s Workbench
Proof of traceability and control over calibration intervals for the standards and instruments used by the system is facilitated by the Calibration Manager.
Tests Performed by the Type 3630-A System
Acoustical:
Electrical:
System Description
Test Modes
Tests are performed either acoustically or electrically. During the electrical tests, the SLM’s microphone is replaced by an adaptor with the same capacitance as the microphone. The adaptor is connected to the system output. The PULSE generator produces all the electrical test signals used during the calibration.
Automatic Mode
If the SLM under test has a bus interface, then setup and reading of data from the SLM is performed...
For a full Description and Specifications, see Product Data