See All Software See All Instruments See All Transducers See All Vibration Testing Equipment See All Electroacoustics See All Acoustic End-of-Line Test Systems See All Academy See All Resource Center See All Applications See All Industries See All Services See All Support See All Our Business See All Our History See All Global Presence
arrow_back_ios

Main Menu

See All Analysis & Simulation Software See All DAQ Software See All Drivers & API See All Utility See All Vibration Control See All High Precision and Calibration Systems See All DAQ Systems See All S&V Hand-held Devices See All Industrial Electronics See All Power Analyzer See All S&V Signal Conditioner See All Acoustic Transducers See All Current and Voltage Sensors See All Displacement Sensors See All Force Sensors See All Load Cells See All Multi Component Sensors See All Pressure Sensors See All Strain Sensors See All Strain Gauges See All Temperature Sensors See All Tilt Sensors See All Torque Sensors See All Vibration See All Accessories for Vibration Testing Equipment See All Vibration Controllers See All Measurement Exciters See All Modal Exciters See All Power Amplifiers See All LDS Shaker Systems See All Test Solutions See All Actuators See All Combustion Engines See All Durability See All eDrive See All Production Testing Sensors See All Transmission & Gearboxes See All Turbo Charger See All Training Courses See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance
arrow_back_ios

Main Menu

See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All API See All Experimental Testing See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Dynamic Weighing See All Vehicle Electrification See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

Calibration of Sound Level Meters (Germany)


The calibration of sound level meters is reserved for the specially equipped calibration offices in Berlin, Dortmund and Munich.

The calibration is the legally prescribed test of a measuring device for compliance with the underlying legal calibration regulations, in particular the calibration error limits. A verification is a legally prescribed calibration that can be traced back to national standards.

Validity and labeling

During the calibration, the device is marked as calibrated by seals and secured against unauthorized access. It may not be opened or otherwise changed during the two-year period of validity. In addition, a calibration label with the data of the device (including the software version and accessories used) is attached.

The calibration becomes invalid if the statutory re-calibration period has expired, one of the security or calibration stamps is damaged or removed, the measuring device does not correspond to the information on the type plate or the measuring device does not correspond to the type approval.

It is advisable to have older devices checked by the supplier before each calibration and, if necessary, adjusted in order to save time and costs for unsuccessful calibration attempts.

What is legal for trade?

According to the Verification Act in conjunction with the Verification Ordinance, sound level measuring devices must be calibrated if they are used in the field of occupational safety or environmental protection to carry out public monitoring tasks, to provide reports for public prosecutor or judicial proceedings, arbitration proceedings or for other official purposes or to provide arbitration reports.

Further details are regulated in Annex 21 to the Calibration Ordinance.

What can be calibrated?

As a rule, a prerequisite is a type test and calibration approval for the relevant sound level meter type by the Physikalisch Technische Bundesanstalt (PTB) in accordance with Annex 21 of the Calibration Ordinance.

The conformity with the requirements of the standards valid at the time of the test is tested and confirmed. These can be, for example, earlier standards such as DIN 45657, DIN EN 60 651 and DIN EN 60 804 or the currently valid DIN EN 61672. Sound level meters that were approved for calibration according to previously valid regulations and have already been calibrated once (initial calibration) can still be recalibrated as long as there has been no interruption of the calibration.

What is being checked?

The calibration includes, an acoustic test of the display under reference conditions and the frequency response in the anechoic room, an electrical test of the frequency weighting(s), the RMS value formation, time weighting(s), scale division, range switch levels, and the inherent noise and the control limits.

In the type test (PTB) (requirement for the calibration of devices), device-typical properties - such as directional characteristics, microphones and environmental influences (temperature, pressure, humidity, vibrations, electrical and magnetic fields) - are examined on five specimens of a type.

New software versions for the sound level meters are presented by the manufacturers to the PTB for verification and may only be installed and used after a new calibration for measurements that are subject to verification.

What should I do?

If your device is being calibrated for the first time, the process must be carried out by the manufacturer of the device using the so-called conformity assessment according to MessEG.

If you want to give a device for recalibration, please contact one of the following calibration offices directly to make an appointment:

Berlin Offices:

State Office for Metrology and Calibration
Lentzeallee 100
14195 Berlin
Tel .: (030) 90 259 617
Fax: (030) 90 259 619
Email: State Office for Metrology and Calibration

Dortmund Offices:

LBME State Office for Measurement and Calibration in North Rhine-WestphaliaKronprinzenstrasse 51
44135 Dortmund
Tel .: (0231) 95 204 115
Fax: (0231) 95 204 144
Email: LBME State Office for Measurement and Calibration

Munich Offices:

LMG Bavarian State Office for Weights and Measures
Eichamt Munich-Traunstein
Franz-Wardrobe-Strasse 11
80638 Munich
Tel .: (089) 17 901 240
Fax: (089) 17 901 233
Email: LMG Bavarian State Office

 

The following are to be sent:

  • The necessary acoustic accessories
  • An informal test order including a list of accessories
  • A device manual (German, possibly with supplements)
  • Fresh batteries in the device.

Special tests

Sound level meters that are not (yet) approved can, under certain conditions, be presented to the PTB for individual or special tests. The scope of the test and costs roughly correspond to a calibration, but it is only certified to a limited extent that the device “in the tested properties” meets the requirements. In addition, certain public and trade association measuring centers have set up their own calibration laboratories for their devices, which are comparable to the calibration offices in terms of equipment and testing.

Our services team is always happy to answer any questions you may have. Get in touch with your local B&K Sales represensatitive to find out more.