See All Software See All Instruments See All Transducers See All Vibration Testing Equipment See All Electroacoustics See All Acoustic End-of-Line Test Systems See All Academy See All Resource Center See All Applications See All Industries See All Services See All Support See All Our Business See All Our History See All Global Presence
arrow_back_ios

Main Menu

See All Analysis & Simulation Software See All DAQ Software See All Drivers & API See All Utility See All Vibration Control See All High Precision and Calibration Systems See All DAQ Systems See All S&V Hand-held Devices See All Industrial Electronics See All Power Analyzer See All S&V Signal Conditioner See All Acoustic Transducers See All Current and Voltage Sensors See All Displacement Sensors See All Force Sensors See All Load Cells See All Multi Component Sensors See All Pressure Sensors See All Strain Sensors See All Strain Gauges See All Temperature Sensors See All Tilt Sensors See All Torque Sensors See All Vibration See All Accessories for Vibration Testing Equipment See All Vibration Controllers See All Measurement Exciters See All Modal Exciters See All Power Amplifiers See All LDS Shaker Systems See All Test Solutions See All Actuators See All Combustion Engines See All Durability See All eDrive See All Production Testing Sensors See All Transmission & Gearboxes See All Turbo Charger See All Training Courses See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance
arrow_back_ios

Main Menu

See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All API See All Experimental Testing See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Dynamic Weighing See All Vehicle Electrification See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

Dassault Aviation Falcon 8X noise certification


Dassault Aviation has performed noise certification tests on their new Falcon 8X business jet, using an acoustic data acquisition and analysis system from Brüel & Kjær.

Exterior aircraft noise certification tests are required by aviation regulators. The tests establish certified aircraft Effective Perceived Noise Levels (EPNLs) for each of the flight conditions: approach, flyover and sideline.

The Brüel & Kjær system uses three GPS-synchronized data acquisition stations that are distributed around the test area. They communicate via WiFi, and are controlled from a central monitoring station.

Each remote location measures and records noise and has a webcam, and one station monitors weather data. The central monitoring station controls the data acquisition, uploads data, interfaces to flight-track data and layered weather data, and calculates results.

The system is based on the modular Brüel & Kjær PULSE LAN-XI data acquisition hardware, which provides the measurement data for the official calculation of EPNL levels. This data is corrected, 1/3rd octave noise measurements compliant with the requirements for aircraft noise certification measurements in accordance with ICAO Annex 16, Volume I, amendment 9.

Brüel & Kjær’s system can also compute EPNL values including background noise, flight track and weather corrections for test validation and management of the tests. While these calculations are not usable for ICAO compliant certification like the 1/3rd octave noise measurement data is, they help testers ascertain their data is valid before ending the test.

The system can also calculate intermediate results such as OAL, PNL, PNL Tmax, PNLT curve and 10 dB down points, which are used during aircraft development testing to ensure designs are on target to meet their requirements.


 

> Get an overview of aerospace and defence news

No more result to load