See All Software See All Instruments See All Transducers See All Vibration Testing Equipment See All Electroacoustics See All Acoustic End-of-Line Test Systems See All Academy See All Resource Center See All Applications See All Industries See All Services See All Support See All Our Business See All Our History See All Global Presence
arrow_back_ios

Main Menu

See All Analysis & Simulation Software See All DAQ Software See All Drivers & API See All Utility See All Vibration Control See All High Precision and Calibration Systems See All DAQ Systems See All S&V Hand-held Devices See All Industrial Electronics See All Power Analyzer See All S&V Signal Conditioner See All Acoustic Transducers See All Current and Voltage Sensors See All Displacement Sensors See All Force Sensors See All Load Cells See All Multi Component Sensors See All Pressure Sensors See All Strain Sensors See All Strain Gauges See All Temperature Sensors See All Tilt Sensors See All Torque Sensors See All Vibration See All Accessories for Vibration Testing Equipment See All Vibration Controllers See All Measurement Exciters See All Modal Exciters See All Power Amplifiers See All LDS Shaker Systems See All Test Solutions See All Actuators See All Combustion Engines See All Durability See All eDrive See All Production Testing Sensors See All Transmission & Gearboxes See All Turbo Charger See All Training Courses See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance
arrow_back_ios

Main Menu

See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All API See All Experimental Testing See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Dynamic Weighing See All Vehicle Electrification See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

Why use an Accelerometer Preamplifier?


Why use an Accelerometer Preamplifier is part of the measuring vibration introduction which answers some of the fundamental questions asked by the newcomer to vibration measurement. It gives an explanation of the following: what is a vibration meter, how to perform frequency analysis using measuring instrumentation, and brief introduction to vibration as a machine condition indicator when conducting machine fault diagnosis.

Download Handbook

CONTENT

  1. Measuring Instrumentation 
  2. Vibration as a Machine Condition Indicator 
  3. Vibration Troubleshooting Chart (A)
  4. Vibration Troubleshooting Chart (B)

Direct loading of a piezoelectric accelerometer's output, even by relatively high impedance loads, can greatly reduce the accelerometer's sensitivity as well as limit its frequency response. To minimize these effects the accelerometer output signal is fed through a preamplifier which converts to a much lower impedance, suitable for connection to the relatively low input impedance of measuring and analyzing instrumentation (1).

In the CCLD accelerometers, the preamplifier is built-in, so no external unit is needed, but an input furnished with the ability to provide the power for the unit is needed. Today this is a very common feature. In addition to the function of impedance conversion, most preamplifiers offer additional facilities for conditioning the signal.

For example:

(2) A calibrated variable gain facility to amplify the signal to a suitable level for input to other instruments;

(3) A secondary gain adjustment to "normalize" awkward transducer sensitivities;

(4) Integrators to convert the acceleration proportional output from accelerometers to either velocity or displacement signals;

(5) Various filters to limit the upper and lower frequency response to avoid interference from electrical noise, or signals outside the linear portion of the accelerometer frequency range;

AccelerometersLEARN MORE
ACCELEROMETERS

(6) Other facilities, such as overload indicator, reference oscillator, and battery condition indicator is also often included;How to measure vibration

Measuring Instrumentation

A portable, general-purpose vibration meter or analyzer will usually be the most convenient and cost-effective measuring instrument to use for machine monitoring and simple vibration assessment tasks.

Very simple instruments exist giving only simple results like total value from 10 to 1000 Hz. However, with modern digital techniques, the cost of adding more features have diminished, so the natural choice is an analyzer with one or two channels and many capabilities of analysis and link to PC. They also include the possibility to add new software.

For more complex tasks the ultimate in operating convenience and analysis speed is obtained with a real-time analyzer, where many parallel frequency bands are evaluated almost instantaneously and shown on a continuously updated display.

Systems with more than 1000 channels are used for large structures.

Single, wide frequency band vibration measurements are a useful quick-look vibration indicator, which can be used for example when evaluating the general condition of a machine or the effectiveness of vibration isolation measures.

The actual level measured will be judged more or less severe by comparison with previously or subsequently measured levels or with published severity criteria. An example of the latter is shown in the drawing, extracted from standards and recommendations for judging the vibration severity of rotating machinery. (ISO 20816-1)

For diagnostic purposes, for example in the course of product development, frequency analysis is necessary. Some frequency components in the vibration frequency spectrum can be immediately related to particular forcing functions, for example, shaft rotation speeds, gear tooth meshing frequencies, etc.

We will almost always find additional significant frequency components in the spectrum which are also related to the fundamental motions. The most significant is usually harmonics (a multiple) of one of the fundamental frequencies. Harmonics often arise because of distortion of the fundamental frequencies or because the original periodic motion is not purely sinusoidal. If they coincide with the resonant frequencies of other machine elements, then possibly considerable vibration levels can result, which can become a major noise source or result in the transmission of high forces to other machine parts.

With gear wheels, tooth form deflection under load and tooth wear will give rise to a tooth meshing frequency component and harmonics.

Furthermore, sideband components are often generated around the tooth meshing frequency and harmonics, due to periodic variations such as eccentricity. The first upper and lower sidebands will appear at the tooth mesh frequency (ft) plus and minus the gear rotation frequency (fg), the second sidebands at ft ± 2fg, and so on. Around the tooth mesh harmonics, a similar pattern may be present (i.e. 2ft ±fg, etc.)

It is often impracticable to alter forcing frequencies (shaft speeds, gear ratios, etc.) so other methods of reducing undesirable vibration levels are used. For example. detuning the machine element (altering its resonant frequency) by changing its mass or stiffness; by attenuating the transmission of vibration with isolation materials, or by adding damping materials to reduce the vibration amplitude.

Accelerometers

Vibration as a Machine Condition Indicator

Machines seldom break down without warning, the signs of impending failure are usually present long before breakdown makes the machine unusable. Machine troubles are almost always characterized by an increase in vibration level which can be measured on some external surface of the machine and thus act as an indicator. The bathtub curve shown is a typical plot of vibration level against time that demonstrates this effect. With normal preventive maintenance, repairs are carried out at fixed intervals based on minimum life expectancy for wearing parts. By delaying repair until vibration levels indicate the need, but before a breakdown, unnecessary strip-down (which often promotes further faults) and production delays are avoided.

This "on condition" maintenance of machinery has proven to give an appreciable economic advantage by increasing the mean time between shutdown while still preventing the surprise and damaging effects of catastrophic failure during service. These techniques are now widely used especially in the continuous process industries.

The vibration level which may be allowed before undertaking a repair is best determined through experience. At present, the general opinion suggests that the "action level" should be set at two to three times (6 to 10 dB above) the vibration level considered normal.

We have already seen that with frequency analysis of vibration signals we can locate the source of many of the frequency components present. The frequency spectrum of a machine in a normal running condition can therefore be used as a reference "signature" for that machine. Subsequent analyses can be compared to this reference so that not only the need for action is indicated but also the source of the fault is diagnosed.

The diagnostic chart on the following two pages will help isolate the cause of excess vibration when the offending frequencies can be discovered through frequency analysis.

Where do Vibrations Come From 

Vibration Troubleshooting Chart (A)

Vibration troubleshooting table A

Vibration Troubleshooting Chart (B)

GET THE FULL HANDBOOK
MEASURING VIBRATION
BY BRÜEL & KJÆR

>DOWNLOAD NOW

Vibration troubleshooting table B