TIPO 9757
Sistema de calibração de baixa frequência
Projetado para a resposta de freqüência de baixa freqüência de microfones de medição e outros tipos de microfone.
Solicite uma cotaçãoUm sistema de calibração de microfone para determinar a resposta de frequência de baixa frequência de microfones de medição e outros tipos de microfone. O sistema, Tipo 9757, aplica um acoplador de comparação de baixa frequência especialmente projetado para as medições.
Type 9757 is a calibration system designed to measure the frequency response of measurement microphones to very low frequencies. A specially designed, low-frequency comparison coupler allows the microphone to be fully inserted into the coupler cavity thereby ensuring that the static equalization vent of the microphone can be exposed to the applied sound pressure even for rear-vented microphones. Sound exposure of the vent during calibration is required if the microphone is intended to be used for free-field measurements.
USE SCENARIOS
- Low-frequency calibration of measurement microphones
FEATURES
- Frequency response calibration by comparison (IEC 61094-5) 0.1Hz to 251Hz
- Calibration of open-circuit or loaded frequency response (that is, response with preamplifier)
- Pressure-field or free-field calibration (that is, vent exposed to sound pressure)
- Dedicated PULSE project for controlling the measurements
- Dedicated Excel workbook for result calculation and presentation
Type 9757 is a calibration system designed to measure the frequency response of measurement microphones to very low frequencies. A specially designed, low-frequency comparison coupler allows the microphone to be fully inserted into the coupler cavity thereby ensuring that the static equalization vent of the microphone can be exposed to the applied sound pressure even for rear-vented microphones. Sound exposure of the vent during calibration is required if the microphone is intended to be used for free-field measurements.
USE SCENARIOS
- Low-frequency calibration of measurement microphones
FEATURES
- Frequency response calibration by comparison (IEC 61094-5) 0.1Hz to 251Hz
- Calibration of open-circuit or loaded frequency response (that is, response with preamplifier)
- Pressure-field or free-field calibration (that is, vent exposed to sound pressure)
- Dedicated PULSE project for controlling the measurements
- Dedicated Excel workbook for result calculation and presentation