Front Panels For LAN-XI
Our LAN-XI modules are compatible with front panels and configured with unique connectors, enabling you to use the same modules for different transducers and setups. The front panels let you decide which cable type to use and make swapping transducers easy, and resulting in fewer patch panels, cable adaptors, less "cable spaghetti" and faster setup time.
-
UA-2100
Default front panel on 4/6 ch. Input Modules Type 3050, 3-ch. Input Module Type 3052 and Generator and 2/2-ch. Input/Output Module Type 3160-A-022.
-
UA-2101
Designed to be used in conjunction with microphones that require 200V polarization voltage.
-
UA-2102
-
UA-2103
6 Channel Sub-D Connector Front Panel
Designed for backwards compatibility with previous Brüel & Kjær Array Acoustic systems.
-
UA-2104
UA-2104 is a front panel specifically designed for sound intensity measurements on PULSE.
-
UA-2105
UA-2105 - Charge Accelerometer Front Panel
Designed for use with charge accelerometers.
-
UA-2107
UA-2107 - 12 Channel High-Density Front Panel
Default front panel for the 12-channel Type 3053 input module
-
UA-2108
UA-2108 - Triax Accelerometer Front Panels
Designed with 2 and 4 x 4-pin triax accelerometer connectors.
-
UA-2109
12 Channel Sub-D Connector Front Panel
Designed for applications where customised non-standard cables are required.
-
UA-2110
Auxiliary Front Panel With 200V Microphone Inputs
Designed for applications combining auxiliary data with microphones that require 200V polarization voltage.
-
UA-2111
Default front panel on both LAN-XI Type 3056 auxiliary modules.
-
UA-2112
Designed for Array Acoustic systems.
-
UA-2113
6 Channel In/Out Monitor Front Panel
Designed to allow input signals to be simultaneously fed into both the LAN-XI system and also a second system like a recorder.
-
UA-2114
Dynamic Bridge Transducer Front Panels
Designed for use with Kulite Bridge Transducers such as the LQ-080 series and the LQ-125 series used in the aerospace industry for dynamic measurements on aircraft and in wind tunnels.
-
UA-2115
Voltage Injection Calibration Front Panel
Designed for Voltage injection calibration when using UA-2115-042 combined with Module Type 3160-A-042 and Microphone Preamplifier Type 2669-W-004.
-
UA-2116
12 Channel Charge Input Front Panel
Designed to allow up to 12 charge type transducers to be connected directly to the LAN-XI frontend.
-
UA-2117
Generator Front Panel For 200 Khz LAN-XI Module
Default front panel for LAN-XI module Type 3161-A-011.
-
UA-2118
Headphone Test, 2 + 2 Channel LAN-XI Front Panel
Front panel for headphone testing designed as a dedicated analogue interface with 2+2 channel headphone testing.
-
UA-2119
6 Channel Differential Charge Input Front Panel
Designed to allow up to six differential charge accelerometers to be connected directly to a LAN-XI frontend.
-
UA-2120
6 Channel Charge Input Front Panel
Designed to allow up to six charge type transducers to be connected directly to a LAN-XI frontend.
-
UA-2121
Designed to be used with LAN‐XI Bridge Module Type 3057‐B‐030.
-
UA-2145
Array Front Panel For 11 LAN-XI Modules
Designed for use with hand-held microphone arrays together with a LAN-XI Frame Type 3660-D.
-
UA-3100
General Purpose Module, Generator
Front panels designed for use with Generator, 4/2-ch. Input/Output Module Type 3160-A-042 or 4/1-ch. Input/Output LAN-XI Light Type 3677.
-
UA-3101
UA-3101 - Façade de frontal CAN Bus
UA-3101 façade livrée avec le module CAN Bus Type LAN-XI 3058
-
UA-3122-030
Differential CCLD Input for Bridge DAQ Module
Charge/CCLD input front panel designed for use with LAN-XI Bridge Module Type 3057.
-
UA-3121
Differential Charge Input for Bridge Module
Differential charge input front panel designed for use with LAN-XI Bridge Module Type 3057.
-
UA-3112
Front panel designed for use with LAN-XI Bridge Module Type 3057.
-
UA-3111-060
UA-3111-060 allows up to six CVLD accelerometers to be connected directly to the LAN-XI front end, simplifying setup and optimizing performance.
-
UA-3102
Generator For 200 V Microphone
Front panel designed for use with Microphones requiring 200 V External Polarization, providing four input channels and up to two generator output channels.